I reset the outlet but nothing works in the coach that’s supposed to when generator is running. 60 instead of 120 volt), then I would suspect a bad voltage regulator. To begin, you need to log into or create an account with Fix.com. Perform this test on both power windings. Assuming there are no problems with the circuit breaker or loose wiring, you may have to flash the generator field. Note that this is one of the many items that our tech team tests during the refurbishment process. Thanks. have a 10k old military gen. runds great BUY no currant.Has a toggle swith to flash.holding toggle switch down will generate enough power to make a 60 watt bulb light but dim .release the flash switch and bulb dies and all meters go back to 0 any clue? Even while holding to start it only reads 83 volts on multimeter and undervoltage fault comes up. It could be a bad breaker as well or a stuck breaker. Hi, I have a 7000W portable generator with a apparent problem. To check on this, keep a voltmeter and ampmeter handy. This is my first time to your forum. So, make sure to hold the Start Switch in the start position until the engine is 100% running continuously plus a couple of seconds and you can avoid this inconvenience. I mean for pay of course. If the generator runs but produces low or no power at all, the first thing that should be checked is the circuit breaker. But you must check breaks in the coach as well as on the generator. The manufacturer will specify which stator lead to use for this test. ... We had a 30min outage about a month ago, generator kicked in and provided power with no issues. My Generator Is Not Generating, But The Engine Runs; Help! I hooked a battery to it (usually pull start it) to try the holding starter switch after its started to try to reenergize the brushes and the a/c light came on for about 2 seconds then back off again. Once this information is found, you can begin testing. The generator may have lost its residual magnetism, which is needed to get the voltage to build up enough to excite the field winding. * Unplug the two wires that connect to the generator brushes. Any suggestions thanks, Hello, Making sure the readout selector on the Control Panel was set to the correct setting (single phase, 110/220 volt). If there is no change in output then check the rotor brushes to make sure they are in good condition and are making contact with the rotor. A home standby generator keeps watch over your home, 24 hours a day, 7 days a week, 365 days a year. Everything was working fine in the house. the motor runs fine when there is no load on it . Did you try holding the starter in the start position even after unit has started? champion generator no power, About J&D Power Equipment J & D Power Equipment, Inc. is an authorized dealer and warranty service center for a variety of Brand-name generators such as Cummins/Onan, Kohler, Generac, Briggs, Winco and Champion providing sales … Making sure the master phase selector switch was in the 110/220 volt position (3 o’clock). Again, if there is any doubt or confusion about this process, take the generator to a professional to have this repair performed. I don’t know but I think it’s from the plug switch which has problems but what do you think it’s the problem?. Started it up to make sure it was still running good as I am selling it. Could be a bad winding or connection on that leg. The generator powers your home so your life can continue. Using a multi-meter set to test resistance, connect the multi-meter to each end of the wire coil using the leads. I put a meter in the receptacle and was getting 2.9 to 3.0 volts. Could also be other issues (e.g. For most 13,500 AC units (most common type on travel trailers), you’ll have no issue powering your AC. email once verification is done. Are you sure you are doing the correct flashing routine? The meter should read “OL” (overload) or Infinity. Cycle the breaker off and on and try the outlet again. Plug in a cord with bare wires on the other end to one of the 120VAC outlets. Look at manual for routine. Got no flashing on the bulbs just light. Hire electrician for safety reasons. The generator may restart just fine, but even after the short built-in delay you may find you have no power in your camper. He put it in his shed and when he took it out next season and started it up it did not produce voltage. August 22, 2017 at 4:11 pm . Featuring Voltmeter, this versatile generator is your perfect portable power solution. Set the multi-meter to test resistance. I have a 30kw military generator engine runs fine but no power can anyone help. Convenient and versatile power is yours with the Champion 5500-watt portable generator. While the unit was running, but not generating electricity, he set the master switch to the “Start” position for 3 seconds to “flash/energize” the electrical field within the generator head. Some electrical component fried. Please help, thanks. Still nothing. This is separate than the VR that controls output voltages fro the generator itself. Each unit can be different. Thanks. I was using the outside outlet on an electric water heater I use in the shop for some hot water. If any of the leads give a resistance measurement that would indicate a short to ground and a bad Stator. We are not very familiar with the HLP 3000. With Avalara CertCapture, you can add your tax exemption certificates to your Fix.com account to purchase tax-free! diesel without battery after about 10 minutes the power goes off and never come on again..any help pls. Should you need to upload, just click the "Import your copy of this document" link in the form. Our incredibly resourceful customer did a quick Google search and found that these symptoms are associated with a non-energized electrical field in the generator head (windings). This will require some electrical troubleshooting to isolate the problem. I would love to build a network of ex military technicians. If any resistance is read, than the breaker is good. If the generator will not start or if it runs poorly after it does start, the spark plug wire may have come loose. We have technicians in the Southern NH region only. Get shopping advice from experts, friends and the community! Thank you, I had the same problem and holding the starter button after the engine started for a few seconds regenerated it ! A generator is a very useful device at times of power outages.Sometimes, your generator may face some problems. My dear,my generator runs well but its output is 200v. Regarding flashing the field on a MEP002a. This MUST match the Phase Selector Switch. 5500W DeVilbiss Generator (I think now they are owned by Porter Cable) 10 HP Tecumseh HM100 Engine also says 159409P on the tag I'm trying to get it running for someone. If it does not, then perhaps we have a no spark issue. You will be taken through a CertCapture request form. Verification is completed within 3 business days. If not, the capacitor should be replaced. Check manual for fuses/breakers and the method to “flash” the unit. Not all generators are identical. Must use a multi-meter and not the on-board meters to rule out bad on-board meters. Possibly need a new voltage regulator. 12 Volt Generator Battery Method. I have an old portable gen that was not producing electricity, first I put the breakers, still nothing, so then I did this trick I know about, you plug a drill into it and turn that drill with a cordless one, worked great. By continuing to use this site you consent to the use of cookies on your device as described in our cookie policy unless you have disabled them. Two things to try: 1. We see you're shipping to . I am not familiar with your specific generator. Hope this helps more folks out there and reduces some blood pressures! my generetor motor is start working but can`t produce electric.would you tell me how i fix it? Carefully remove and reseat the spark plug wire and try to start the generator again. Check the main grounds. It could be a safety circuit preventing power. Check all ground connections from controls to frame. To test a brushless stator, the wires from the stator to the electrical panel will first need to be removed. He put it in his shed and when he took it out next season and started it up it did not produce voltage. I have flashed the unit twice and not change. Carefully remove and reseat the spark plug wire and try to start the generator again. If the meter reads ‘OL’ (overload) or Infinity, the breaker is bad and should be replaced. Hello, I have acquired a Champion C46535 4000 watt peak Generator from a family member. Verify that the correct amount of oil is in the engine. Also I’m in Maryland are there knowledgeable people who can come and look at it out there? Tried the “energizing” method with the bulbs and the drill. You might hear the generator struggle and then die. If your home experiences a power outage, your faithful home standby generator can step in immediately. If the generator will not start or if it runs poorly after it does start, the spark plug wire may have come loose. It depends on the type of generator (make and model). The sensor may stick on engines that have not been run for long periods of time. If your generator engine is running but is producing no or low output, the circuit breaker is the first thing you should check. If this doesn’t resolve the problem, take the generator to a certified Champion dealer for service. Never had any problems, it ran my entire house except A/C. I assume all breakers are on and you have checked output at lugs. The governor does not reduce the speed and only holds the throttle fully open. When I turn on the toaster, the output voltage drops to 110 volts and 59hz. Your unit may require batteries to be operational at all times. The engine started normally and everything seemed 100%, except for one issue: no electricity was being generated to the main terminals or the convenience outlet. Adding a certificate takes only a few moments. Still not sure which part is broken? The breaker is a safety feature designed to automatically switch off if a surge of electricity or overload is detected. The model number and serial number are located on the side of the generator with the handle, on a tag on the crossbar above the yellow generator … Have ridgid generator turns on no output, replaced the voltage regulator still no output . Have any idea what it could possible be. What’s your thoughts? If everything tests good up until this point, test the stator itself. Strange its the villiars es model 6kva. The power came back on when my generator was running and plugged in power went in to the generator from power line ,now it will not make any power.jim, Please use the GMG Contact form on our website. Please consult manual. Generac, Guardian, Honeywell, Siemens, Centurion, Watchdog, Bryant, & Carrier Air Cooled Home Standby generator troubleshooting and repair questions. There are two types of stators used in generators; brushed and brushless. By high power we include things like the air conditioner and perhaps your coffee maker. Voltage Regulator is in the main control box (the main box with meters, switches that controls the unit). We have an 806A that the field wont stay flashed when we release the Start switch. Check batteries and connections. This will restore the capacitors charge. Some excite right away. Check to make sure your grounds and neutral circuits are also good. I can spray starting fluid into the intake, choke it, engine will catch on the first pull but won't stay running. If I don’t wait, the engine will shut off if I release the switch too soon. There is an Anti-Restart switch on the engine that disengages the starter after the engine starts. I have an MEP006A in which the engine runs great. Should you need to upload, just click the “Import your copy of this document” link in the form. Check rheostat and voltage regulator. This is needed to start off the generation. Our next step would be to check the alternator. 0 0. He is not mechanically inclined whatsoever so he just bought a new one and gave me the old one. This moter powers an 1800 watt generator and a [email protected] psi high pressure water pump. At least, it runs my We have received your CertCapture request form for . my 6500 onan generator bought this in 2008 it starts but run half or less power. Connect one end of the cord to a car battery. To discharge, use a screwdriver with an insulated handle to cross the terminals on the capacitor (this will result in a loud pop and a spark). I have an Onen 4.0 RV in my motor home. This can happen if it has been a long time since the generator was used, or was run a long time without load, or a load on without running. Could be many things such as bad generator head (short, bad winding, diode problem). If a spark does appear, reconnect the white wire to its terminal and there should be power to the outlets and meter. Most small generators do not have magnets but have two sets of coils, one that spins and one that is stationary. It’s running lovely but before the voltage gage went up only when I plugged something in but now nothing on gage and no power??? Connect the harness to the capacitors terminals and plug in the plug end to a 120v outlet. GMG, I need a company which can fix my generator or recoil it since is not producing power and the engine it’s working. Verification is completed within 3 business days. The next test will check for a short between the windings and ground. They had more color to add to what was going on. First off, you should NEVER backfeed through a 220 or dryer outlet. Thanks for the reply so far. If by half power, you mean half the voltage. As with all military generators the Master Switch is to be held in the start position long enough to start the engine AND excite the field windings in the generator itself. He bought the generator new for his rv and used it one season and it worked fine. One of our recent customers had a small scare with their new generator. I recently bought a Blackmax powered by Honda generator 8750/7000. ... my generac np52g generator runs great but sometimes it will not produce electricity and sometime it will once it starts producing it is fine and will contuine to produce until it s turned off. (Remove the bolt below the red wire. The magnetically charged rotor rotates inside of the fixed stator windings, which produces electricity. Could be breakers. One of the test leads should be connected to a clean frame ground, and the other used to test each of the leads from the stator. Where is the voltage regulator? There are a few methods of restoring a generator residual magnetism 12 Volt Generator Battery Method * Locate the voltage regulator for your generator. To test a capacitor, a multi-meter that can test capacitance is required. Set your multi-meter to test resistance. First, you must use a multi-meter and not the on-board meters, which can always be bad or inaccurate. The generator might need to be flashed if it has been sitting or the batteries have gone bad. Wish we could offer more help! I’ve done everything even removed the exhaust thinking its giving feedback but all the same. You need to have a good multi-meter to rule out a bad meter. 60Hz = 1800 or 3600rpm (depending on your engine). The Champion 9375 Generator isn’t just for emergency use during a power outage, as it’s also ideal for operating 4 to 5 power tools or an air compressor. Each lead should read “OL” (overload) or Infinity. For one of the highest energy standards in the whole house generator market, the Briggs & Stratton 40346 remains of the best picks. Champion Power Equipment engines come equipped with a low oil sensor that prevents the engine from running when too little oil is in the crankcase. It worked fine 2 weeks ago, I don’t understand it. A single pole momentary switch is added to the live or positive side of the wiring harness. This corresponds to an 1800 rpm engine which is controlled by the throttle/governor vernier/twist cable. I’m wondering if what’s causing the problem is one of the breakers. I hold the start switch till it runs on its own and a Lil longer it excite then it drops if u hold it it will stay but not stay, I have a 30kw military generator engine runs fine but no power can anyone help. EF1000 runs but no power. A surge can be caused by using a device that draws more power than the breaker is rated for, using multiple ‘heavy load’ devices at the same time, or if a short occurs within the circuit. (Jets usually clog only if you used dirty fuel or let it sit a long time (years) so it turned to varnish.) Featuring Volt Guard™, this generator is your perfect portable power solution. The first test will determine if there is an open circuit within the winding, which would indicate a damaged or broken winding. Your unit might just need to be flashed. Like ex military. Thanks guys, the first suggestion worked. Rely on the Champion 389cc engine and enjoy up to 9 hours of run time at 50% load with a noise level of 74 dBA. Adding a certificate takes only a few moments. 22 kw open type generator in engine running ok , electric current not coming but unload time current coming , loading time current no coming. I have a HLP 3000 military 3kw diesel generator set. Topic: Champion 3500 Watt Generator (UPDATED and FIXED) Posted By: Prowler Doug on 03/07/10 10:18pm Have had the unit for 2 years, today I fired it up started on the 2nd pull but I have no power being generated. Adjusting the idler screw seems to have helped but it is causing the generator to idle higher than it should under no-load and it still want to pulse sometimes. The generator seems to also run smooth if I turn some appliances on and place it under load. Hello all, my name is Ron. http://www.endtimesreport.com/dead_gen.html. Used it a couple months ago and it couldn’t handle my water heater, bogged the engine down, then lost all voltage and nothing on voltage or hertz meters. We will notify you via email once verification is done. Generac Generator runs but produces NO POWER? We wanted to dig a little more deeply, so we provided the scenario to our technical staff. Sometimes a leg can get stuck open (hence why you need to check power just before and after breaker to pinpoint failure point). The test leads will be connected to two of the stator leads specified by the manufacturer. It generates power but only when the start switch is held up constantly. Need to check the windings. Your generator is also recharging your house battery or batteries, so you may be drawing more power than you know about. Todd. I recently bought an 002a from Government Surplus. The two leads will be one lead from each of the power windings. Nothing dramatic, just puzzling. Topic: Champion 3500 Watt Generator (UPDATED and FIXED) Posted By: Prowler Doug on 03/07/10 10:18pm Have had the unit for 2 years, today I fired it up started on the 2nd pull but I have no power being generated. To test a capacitor, it must first be removed from the generator and discharged. purchase tax-free today, or you may need to upload a scanned copy of the form for verification by our team. Ugh! Again, the manufacturer will need to specify which leads to use for this test. You need to ensure that the unit is running at 60Hz. My genorator is running perfectly fine but it will not put out any electricity. Need to check before and after the master breaker. Could be misue of generator (i.e. I have an All Power 3250 Watt Generator model APG3012- it starts up and runs fine, but does not produce electricity. Seems like engine is good, yes? Assuming you have an electric start unit, your voltage regulator (the one that controls battery charging) could be bad. August 16, 2017 at 11:07 am . If your generator engine is running but is producing no or low output, the circuit breaker is the first thing you should check. gmg says: Could be a bad main AC circuit breaker. Note that the above pertains to MEP-002A and MEP-003A units, but may also pertain to other models. As always, send us your questions and tips so that others can benefit! With its 439cc OHV engine, the generator can run for 9 hours at 50% load with tankful of gas. The AVR is a circuit that regulates and balances the amount of voltage being output from the generator. You can electrocute yourself or a utility worker or fry your generator. Let's begin adding your tax exemption certificate(s) to your FIX account. You will need to consult an electrician. Some breakers will have colored indicators to show if they have been tripped, but some will not give any indication at all. Locate the voltage regulator for your generator.Unplug the two wires that connect to the generator brushes. This worked! Check all wires (mice are a big problem), check all breakers to make sure they have not tripped. To charge the capacitor a special charging harness must be constructed consisting of a short length of 12-gauge wire with a standard 120v plug on one end. It’s connected to a transfer switch in the house. but as soon as i pull … read more Chris Huber However I have a similar problem to what is describe above. What meter are you looking at (% load or voltage)? You can play with this while the unit is running. But you will need to ensure all connections are good, no shorts, and the unit should be grounded properly.